Description
DISONCARE Odyssey BC-B001 Medication Cooler
The DISONCARE Odyssey BC-B001 is a passive medication travel cooler with a Standard Lid, designed for carrying selected compatible injection devices during travel.
Its vacuum-insulated stainless-steel body works together with the prepared Blue BioGel Bottle to provide portable cooling support without electricity or active refrigeration.
- Flexible 1–3 Pen Range
- Up to 60 Hours of Cooling Support under controlled test conditions
- Standard Lid — no built-in temperature display
- 304 stainless-steel vacuum-insulated construction
- Designed for air travel, road trips, daily carry, and longer journeys
Injection Device Fit & Capacity
Odyssey provides more usable carrying space than the compact Holiday Series while remaining portable for everyday and travel use.
Depending on the exact device dimensions and packing setup, Odyssey can accommodate:
- Up to 3 selected common insulin pens
- Up to 2 selected multi-dose GLP-1 injection pens
- Up to 1 selected wider injection device
Injection devices can vary significantly in length, width, diameter, cap design, and overall shape. The medication name alone does not determine physical fit.
For example, a multi-dose injection pen and a wider single-dose injection device may require very different amounts of internal space.
Before ordering, check your exact device with the Odyssey Medication Cooler Fit Guide .
Dimensions & Usable Space
- Overall Size: 9 × 2.5 in / 23 × 6.5 cm
- Usable Internal Height: approximately 6.5 in / 16.5 cm
- Internal Chamber Diameter: approximately 2.28 in / 5.8 cm
- Maximum Clearance Beside BioGel: approximately 1.29 in / 3.3 cm
The 1.29 in / 3.3 cm clearance beside the BioGel Bottle is not a universal maximum device diameter. Actual fit depends on the device shape, orientation, protective pouch, and complete packing arrangement.
For the most reliable comparison, check the full length and widest external dimensions of the exact injection device you plan to carry.
Cooling Performance & Test Conditions
Odyssey BC-B001 uses the prepared Blue BioGel Bottle together with vacuum-insulated stainless-steel construction to provide passive cooling support.
It does not electrically regulate the chamber to a fixed temperature.
| Ambient Temperature | Approx. 2–8°C / 36–46°F | Approx. 2–25°C / 36–77°F |
|---|---|---|
| 30°C / 86°F | Up to 36 hours | Up to 60 hours |
| 35°C / 95°F | Up to 32 hours | Up to 50 hours |
| 40°C / 104°F | Up to 30 hours | Up to 48 hours |
Up to 60 hours does not mean the cooler remains between 2–8°C / 36–46°F for the full 60 hours. The stated maximum cooling duration includes the broader 2–25°C / 36–77°F test range under the stated conditions.
Actual cooling performance varies with ambient temperature, BioGel preparation, device load, packing arrangement, how often the cooler is opened, and other travel conditions.
Always follow the storage instructions provided with your specific medication. DISONCARE cooling-performance data describes the cooler and test setup and does not determine whether a medication remains suitable for use after a temperature excursion.
Prepare the Blue BioGel Bottle
The Blue BioGel Bottle is the primary cooling component used with the Odyssey Series.
- Freeze the Blue BioGel Bottle at approximately −18°C / 0°F for 6–8 hours, or until fully frozen.
-
After removing it from the freezer, either:
- leave it at room temperature for approximately 15–30 minutes; or
- rinse the outside under normal tap water for approximately 30–60 seconds.
- Place the injection device in the included protective pouch, its original packaging when appropriate, or another suitable barrier.
- Avoid prolonged direct contact between the injection device and the freshly frozen BioGel Bottle.
This preparation helps moderate the initial surface temperature of the freshly frozen cooling component. It should not be interpreted as a guarantee that medication cannot freeze.
How to Pack the Odyssey BC-B001
-
Freeze the Blue BioGel Bottle.
Prepare it at approximately −18°C / 0°F for 6–8 hours. -
Prepare the BioGel before packing.
Leave it at room temperature for approximately 15–30 minutes or rinse the outside under normal tap water for approximately 30–60 seconds. -
Prepare your injection device.
Use the included protective pouch, original packaging when appropriate, or another suitable barrier. -
Load the cooler carefully.
Arrange the device and BioGel Bottle without forcing, bending, or compressing the injection device. -
Close the Standard Lid securely.
Confirm that the contents are positioned correctly before travel. -
Avoid unnecessary opening.
Frequent opening allows warmer outside air into the cooler and can reduce cooling duration.
Emergency Bottle
The Emergency Bottle can be used as part of the Odyssey extended cooling setup when needed.
It should not be interpreted as adding a fixed number of cooling hours to the Blue BioGel Bottle. Overall cooling performance depends on the complete cooling setup, ambient temperature, preparation, device load, packing arrangement, and travel conditions.
Never pour loose ice or water directly into the main stainless-steel cooler body.
Standard Lid
BC-B001 is the Standard Lid version of the Odyssey Series and does not include a built-in digital or mechanical temperature display.
If you prefer an Odyssey model with an interior air-temperature reference, compare:
- BC-B004 — Digital Temperature Display
- BC-B006 — Mechanical Dial Temperature Display
The temperature-display versions provide a reference to the air temperature inside the cooler near the sensor or probe. They do not directly measure medication temperature, liquid temperature, or determine whether medication remains suitable for use.
Designed for Air Travel
Odyssey BC-B001 is designed as a portable medication cooling container for air travel and carry-on use.
DISONCARE does not claim that the cooler is officially TSA-approved, TSA-certified, or endorsed by TSA. Medication, cooling components, and the cooler itself may be subject to airport security screening.
For international travel, airline, airport, customs, and medication requirements can vary by country and route. Check the requirements that apply to your journey before departure.
For detailed flight preparation, read How to Pack Your DISONCARE Cooler for Flights .
QR Information Tag
The DISONCARE QR information tag can provide access to contact and emergency information that the owner chooses to make available.
If the cooler is found during travel or everyday use, the QR tag may help the finder identify how to contact the owner or an emergency contact.
The QR information tag is an information feature. It does not track the cooler's location, guarantee recovery of a lost item, or represent TSA identification or approval.
Which Odyssey Model Should I Choose?
Odyssey BC-B001, BC-B004, and BC-B006 share the same general cooler-body and capacity concept. The main difference is the lid:
- BC-B001: Standard Lid
- BC-B004: Digital Temperature Display
- BC-B006: Battery-Free Mechanical Dial
Choose BC-B001 if you want the Odyssey carrying capacity and passive cooling setup without a built-in temperature display.
To compare Odyssey with Holiday and Intercontinental, visit the DISONCARE Medication Cooler Fit Guide .
Important Product Information
Cooling container only. No insulin, medication, prescription drug, or injectable product is included or sold with this item.
Medication storage requirements vary by product, formulation, injection device, market, and individual circumstances. Always follow the current storage instructions supplied with your medication.
If you are unsure whether a medication remains suitable after freezing, overheating, or another temperature excursion, contact your pharmacist, healthcare provider, or medication manufacturer for product-specific guidance.









